⚠ Under heavy construction

As of July 11, 2026, Sorter V2 is not yet in a position to be built.

The documentation that exists is incomplete. Any given page may be accurate, inaccurate, present only as an example, or badly out of date. We do not yet recommend that anyone attempt to build Sorter.

For the most live updates on our progress, join our Discord.

Sorter Happy Path / Incident Inventory

Happy Path

The normal sorter loop should stay boring:

  1. C1 feeds only while the C2 dropzone can accept a piece.
  2. C2 advances pieces toward C3 and only feeds when C3 can accept one.
  3. C3 feeds C4 only when C4 has an open gate or a pending C4-to-C3 intake request.
  4. C4 tracks, classifies, and drops a resolved piece into distribution when the chute is ready.
  5. Distribution selects a bin, moves chute/door hardware, commits the piece, and reopens the gate after physical exit.

Anything that requires recovery motion, operator judgement, hardware repair, or intentional fallback should be an incident instead of being blended into that flow.

Explicit Incidents

KindScopeTriggerCurrent resolution
exit_stuckC2/C3/C4A piece is not falling off a channel.Operator or automatic release wiggle, depending on policy.
channel_dropzone_stuckC2/C3A detected piece stays in a dropzone during accumulated channel motion.Operator/auto acknowledges the track is ignored until it leaves the dropzone.
c2_separation_neededC2C2 would have started slip-stick separation.Manual review; automatic motion intentionally disabled for now.
bulk_feeder_stalledC1C1 has pulsed enough times for long enough without new C2 activity.Operator checks the bulk feeder or clears the incident.
feeder_detection_unavailableC2/C3/C4Feeder camera detections are unavailable past the grace window.Operator restores detection or clears the incident.
distribution_servo_bus_offlineDistributionEvery configured distribution layer servo is offline.Operator restores the bus; incident clears when a servo reports healthy or can be manually cleared.
distribution_no_bin_availableDistributionNo matching bin/capacity is available for the piece.Operator assigns capacity, frees a bin, or clears the incident to approve one-shot bottom-tray passthrough for that piece.
classification_unresolvedC4C4 reaches the drop deadline or Brickognize timeout before the piece is resolved.Operator reviews the fallback-to-unknown and clears the incident.
classification_multi_drop_collisionC4Multiple pieces reach the C4 drop window together.Operator inspects the collision/fallback and clears the incident.
classification_intake_request_timeoutC4C4 requested a piece from C3, but no intake track arrived before timeout.Operator checks the C3→C4 handoff and clears the incident to retry.
classification_track_lostC4A meaningful C4 track expires from stale-zone cleanup before the expected drop flow completed.Operator checks C4 tracking/occlusion and clears the incident. Empty ghost tracks remain diagnostics only.

Explicit Non-Incident Modes

These paths are intentionally separate from normal sorting, but they are not operator incidents:

ModeCurrent behaviorWhy it is not an incident
camera_sample_collection_bypassSample collection bypasses some gates and speed limits.This is an explicit operating mode, not an incident, but it should stay visibly separate from normal sorting.