Engineering notes — kvdd

A partial power stress run on Kitbash

Reference

What one sorter drew from the wall while every stepper, servo and the chute ran at once, and what that says about sizing its power supply.

On 25 August 2026 Kitbash (spencer-02) ran the backend's power stress test with a smart plug measuring its wall draw. The run was cut short: 7 min 7 s of the planned 10 min completed. It still gives a useful provisional envelope.

Across the 427 seconds, wall draw averaged 62.9 W, reached 68.3 W at the 95th percentile, and peaked at 69.9 W, about 7.45 Wh in all. The run stopped because the firmware rejected a command to move servo channel 2 to 0°, not because of power: the plug read 62.9 W at 118.0 V on that sample, and Kitbash went back to ready with no hardware error.

This is not a completed worst-case qualification. Only 19 of the planned 200 mixed-mode seconds ran, the plug samples about once a second and can miss shorter peaks, and the servos had no mechanical load.

Wall power over the run: a short spike for the first 12,000 microsteps per second attempt, then a plateau near 65 W through the stable phase, a slightly lower and noisier plateau through the random phase, and a drop to about 26 W after the servo rejection
Wall power through the run, about one reading a second, with the phases shaded.

What ran

ItemSetting
Target duration600 s
General stepper speed6,000 microsteps/s
Chute speed3,000 microsteps/s
Chute maximum345°
Non-chute steppers4
Servos3
LED outputs2, full on during the run
Perception workers3 of 3 alive
Configured camera roles5
Distribution firmwarefirmware/v0.8.0, distribution-v1-2 target
Run id9fafd9e1-178a-46bc-ba4d-00bd19981b29

The chute homed before motion began. The physical v1.3 distribution board identifies as, and is released under, the distribution-v1-2 firmware target.

Wall power

WindowCompletedMeanOver the pre-run floorP95PeakEnergy, about
Pre-run ready floor28 s sampled20.7 W21.9 W22.0 W0.16 Wh
Preparation and chute home5.4 s24.8 W+4.1 W25.9 W25.9 W0.03 Wh
Stable: all four steppers continuous, chute and servos sweeping201.1 s64.8 W+44.1 W69.0 W69.9 W3.60 Wh
Random: all four steppers bursting, chute and servos random200.9 s61.9 W+41.2 W65.0 W67.9 W3.43 Wh
Mixed segment 1: two continuous and two burst steppers19.0 of 45 s63.6 W+42.9 W66.9 W67.3 W0.33 Wh
Whole main run427.0 s62.9 W+42.2 W68.3 W69.9 W7.45 Wh
Post-run ready state55 s sampled25.6 W+4.9 W26.6 W26.8 W0.38 Wh

The plug held 117.9 to 118.5 V through the run. Mean AC input current was 0.883 A and the highest reading 0.975 A. Voltage times current gives about 104 VA mean and 115 VA peak; the gap to real watts is the load's power factor, which matters for upstream AC wiring, a UPS or an inverter.

The highest sustained load was the stable phase, all four non-chute steppers running continuously. Random stopping and starting did not exceed it at the plug's one-second resolution.

How the load is spread

Left, box plots of power by mode: about 21 W ready, 25 W preparing, 65 W stable, 62 W random, 64 W mixed. Right, the load-duration curve: 68.3 W for 5% of samples, 63.3 W for half, 59.2 W for 95%
Power by sorter mode, and the share of the run spent at or above each load.

This was a sustained load, not one spike. Half the main-run samples were at or above 63.3 W, a quarter at or above 65.0 W, and 5% at or above 68.3 W. Even 95% were at or above 59.2 W; the low tail is preparation and the cleanup between phases.

Stable continuous motion had a 65.0 W median and a 64.8 W mean, random burst motion a 61.9 W median and mean. That 2.8 W difference between the modes is more useful for sizing than the command rate.

Power and what the sorter was doing

Three stacked charts over the run: wall power on top, the number of non-chute steppers moving in the middle (four throughout the stable phase, zero to four in the random phase), and commands per five seconds at the bottom, far more in the random phase
Wall power lined up with the actuator commands in the sorter's journal, commands counted in five-second bins.

The chart lines the plug's readings up with the move_at_speed, servo-target and chute-move messages in the sorter's journal. Which non-chute steppers were running was reconstructed from every nonzero and zero speed command.

ModeNon-chute steppersStepper start/stop commandsServo target commandsChute move commandsMean power
Stableall 4 moving continuously43181964.8 W
Random0 to 4 moving as bursts overlap94647317261.9 W
Mixed, partial2 continuous plus 2 bursting4142163.6 W

Command count is not a power proxy. Random mode sent far more commands and drew less power than stable mode. Within the random and mixed runs, one-second power against the number of non-chute steppers moving had a Pearson r of about 0.04, no meaningful linear relationship at this resolution: enabled drivers hold current while stopped, bursts change faster than the plug integrates, and the chute and servo loads overlap.

The operating mode says more than individual commands: four continuously moving steppers added about 2.8 W over burst mode, and both stayed on a 62 to 65 W plateau. Size a supply from the phase envelope and the observed peak, not from a per-command estimate.

Timeline

Warehouse time, EDT.

TimeEvent
22:03:39First attempt at 12,000 microsteps/s started.
22:03:44It stopped after 5.2 s on a stall on channel 4. It peaked at 59.6 W and never reached a steady state.
22:04:18Main run at 6,000 microsteps/s started; chute homing began.
22:04:23Chute home completed at 66.75°, LEDs set fully on, all three perception workers alive. Stable phase started.
22:07:45Stable phase completed: 106 to 108 servo commands per channel, one continuous command per non-chute stepper. Random phase started.
22:11:06Random phase completed: 233 to 241 stepper start/stop commands and 157 to 161 servo commands per channel. Mixed segment 1 started: channels 1 and 3 in bursts, 2 and 4 continuous, servos random, the chute sweeping.
22:11:24Servo channel 2 was sent from 180° to 0°; the firmware rejected the command as busy or disabled.
22:11:25The runner recorded the failure and cleaned up.
22:11:29Wall draw was down to 26.4 W.

Why it stopped

The run ended on Servo 2 rejected target 0. The host had seen the servo as stopped before sending the move, but the firmware refused it, and its answer does not tell a transient busy state from a disabled one, so the firmware-side cause is still open.

Nothing points at the incoming power:

  • The plug read 118.0 V at the failure, inside the run's 117.9 to 118.5 V.
  • Real power was still 62.9 W when the failure was recorded.
  • No plug reading was missed during the test.
  • Kitbash stayed online, cleanup ran, and the hardware returned to ready with no error.

The first attempt at 12,000 microsteps/s stopped on channel 4's stall guard. The 6,000 microsteps/s run then carried all four steppers through the whole stable and random phases, so 6,000 is the highest speed this session demonstrated, not a physical or electrical maximum.

What it means for the power supply

For one supply covering the same load as this outlet:

  • Measured wall peak: 69.9 W real power, sampled once a second.
  • Provisional minimum: 100 W continuous, about 43% over the measured peak.
  • Provisional preference: 120 W continuous, about 72% over the peak, for transients shorter than a second, loaded servos and the mixed sequence that did not run.
  • Upstream AC or UPS: at least 115 VA from the measured voltage times current, plus the usual design margin.

This does not settle the current any single DC rail needs. The plug measures the whole AC input: the Orange Pi, cameras, NPU, lighting, servos, motor electronics and conversion losses. Choosing the DC supply still needs output voltage and rail current measured, or a known rail layout and efficiency budget.

Limits of the measurement

  • The plug samples about once a second. Shorter motor and servo transients can go above 69.9 W.
  • It measures one outlet: Kitbash and its distribution motor rail. Anything powered from another outlet is not in it.
  • The mixed phase ran for 19 seconds, and four later mixed segments did not run: about 70% of the scheduled motion completed.
  • The servos were driven but mechanically free. Installed mechanisms can draw more servo current.
  • Each plug reading is timed when it arrived, so it lines up with the machine's events to within about a second.

The run's own records are the backend's power stress runs 85a0595f-48e1-4509-9ff0-5795daafcd27 and 9fafd9e1-178a-46bc-ba4d-00bd19981b29, the sorter journal for 22:03 to 22:12 EDT, and about 700 one-second plug readings covering the test and the baseline around it.

Next measurement

Once the servo rejection is handled, repeat the 600-second run at 6,000 microsteps/s, and treat the result as final only after all five mixed segments complete. If the supply decision lands close to this envelope, measure rail current at a higher rate before going below the 120 W provisional figure.

This note is permanent and is not edited after the fact. If the situation changes, a new note supersedes it and this one stays where it is.